Skip to main content

Posts

Showing posts from 2014

Best orthopedic surgeon in jayanagar Bangalore

Computer navigation in knee replacement surgery in bangalore
ortho one orthopedic and joint replacement centre http://goo.gl/maps/VO3tM

Best orthopedic doctor in bangalore - Dr Deepak Inamdar (for appointments please use this)

              http://www.qikwell.com/clinics/orthoone-orthopedic-joint-replacement-centre

COMPLEX REVISION TOTAL HIP REPLACEMENT WITH PROXIMAL FEMORAL REPLACEMENT IN A 40 YR OLD

                                                   40 YR OLD CAME WITH THIS SHE HAD HIP PAIN ON LEFT SIDE , THIS WAS DONE 25 YRS BACK(??TUMOR)- WE PLANNED A THR WITH PROXIMAL FEMORAL REPLACEMENT PROSTHESIS CEMENTED STEM UNCEMENTED PINNACLE GRIPTION CUP CERAMIC HEAD POST OP X RAY

COMPLEX REVISION HIP SURGERY IN A 73 YR OLD WITH FAILED HIP SURGERY (done elsewhere) ,Bangalore , INDIA

73 YR old female , operated elsewhere with a failed hip fracture surgery came to us , with this preop CRP - TC -WNL we planned a revision -calcar replacement stem(intraop gram stain negative for bacteria) cables and wiring (charnleys ) for trochanter wiring of trochanter calcar replacement long stem- in place with wires bipolar head introduced prosthesis reduced wiring of trochanter done with cable(CHARNLEY) post op x ray

Complex total hip replacement surgery in a patient with protrusio acetabuli (rheumatoid arthritis) ,- bangalore , india

65 yr old , rheumatoid arthritis lady came to us on a wheel chair, not able to walk - she had a history of RA , on steroids , osteoporotic bone and diabetic pre op plan - correct shortening of 2 cms lateralize hip center build up base of acetabulum with mashed morcelized bone graft use oversized cup to get a peripheral fit with screws v. off set 54 mm and h offset 50 mm we used pinnacle uncemented cup - 180 degree coverage                                                      cup insitu fixed with two screws neutral liner UHMWHDP LINER INSITU SUMMIT UNCEMENTED STEM COCR -32 HEAD COCR HEAD INSITU HEAD MATED TO SUMMIT STEM AIMS ACHIEVED- shortening 2 cms - gained cup lateralized  cup 50 peripheral fit and offset targets achieved intraop in addition - iliopsoas , adductor and it band released